Please use this identifier to cite or link to this item: http://dspace.uniten.edu.my/jspui/handle/123456789/11159
DC FieldValueLanguage
dc.contributor.authorShukeri, W.F.W.M.en_US
dc.contributor.authorMat-Nor, M.B.en_US
dc.contributor.authorJamaludin, U.K.en_US
dc.contributor.authorSuhaimi, F.en_US
dc.contributor.authorRazak, N.N.A.en_US
dc.contributor.authorRalib, A.M.en_US
dc.date.accessioned2018-12-07T00:30:34Z-
dc.date.available2018-12-07T00:30:34Z-
dc.date.issued2018-
dc.description.abstractBackground and Aims: Currently, there is a lack of real-time metric with high sensitivity and specificity to diagnose sepsis. Insulin sensitivity (SI) may be determined in real-time using mathematical glucose-insulin models; however, its effectiveness as a diagnostic test of sepsis is unknown. Our aims were to determine the levels and diagnostic value of model-based SI for identification of sepsis in critically ill patients. Materials and Methods: In this retrospective, cohort study, we analyzed SI levels in septic (n = 18) and nonseptic (n = 20) patients at 1 (baseline), 4, 8, 12, 16, 20, and 24 h of their Intensive Care Unit admission. Patients with diabetes mellitus Type I or Type II were excluded from the study. The SI levels were derived by fitting the blood glucose levels, insulin infusion and glucose input rates into the Intensive Control of Insulin-Nutrition-Glucose model. Results: The median SI levels were significantly lower in the sepsis than in the nonsepsis at all follow-up time points. The areas under the receiver operating characteristic curve of the model-based SI at baseline for discriminating sepsis from nonsepsis was 0.814 (95% confidence interval, 0.675-0.953). The optimal cutoff point of the SI test was 1.573 × 10-4 L/mu/min. At this cutoff point, the sensitivity was 77.8%, specificity was 75%, positive predictive value was 73.7%, and negative predictive value was 78.9%. Conclusions: Model-based SI ruled in and ruled out sepsis with fairly high sensitivity and specificity in our critically ill nondiabetic patients. These findings can be used as a foundation for further, prospective investigation in this area. © 2018 Indian Journal of Critical Care Medicine | Published by Wolters Kluwer - Medknow.en_US
dc.language.isoenen_US
dc.titleLevels and diagnostic value of model-based insulin sensitivity in sepsis: A preliminary studyen_US
dc.typeArticleen_US
dc.identifier.doi10.4103/ijccm.IJCCM_92_18-
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:UNITEN Scholarly Publication
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.