Please use this identifier to cite or link to this item: http://dspace.uniten.edu.my/jspui/handle/123456789/13319
DC FieldValueLanguage
dc.contributor.authorNaganathan, S.en_US
dc.contributor.authorChakravarthy, H.G.N.en_US
dc.contributor.authorAnuar, N.A.en_US
dc.contributor.authorKalavagunta, S.en_US
dc.contributor.authorMustapha, K.N.B.en_US
dc.date.accessioned2020-02-03T03:31:48Z-
dc.date.available2020-02-03T03:31:48Z-
dc.date.issued2019-
dc.description.abstractThis paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling. © 2019, Korean Society of Steel Construction.
dc.language.isoenen_US
dc.titleBehaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRPen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s13296-019-00293-5-
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:UNITEN Scholarly Publication
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.