Title: Root Cause Failure Analysis (RCA) of Above Ground Vertical Storage Tank Damaged Plate
Authors: M.A.Khattak 
Rizwan Ali 
Raju Aji 
Wayne Robinson 
Rahul Deo Sonar 
Shafi Noor 
Sameer Sameen 
Abdoulhdi. A. Borhana 
Keywords: Storage tanks
Erosion
Corrosion
Issue Date: Jan-2019
Journal: Journal of Multidisciplinary Approaches in Science 
Abstract: The above ground storage tanks (AST's) in the refinery is experiencing an extensive damaged bottom plate of an above ground vertical storage tank. This has resulted in the 12mm elliptical hole failure of 1 tank since its commissioning (1982). This report summarizes the results of the non-destructive evaluation (NDE) carried out to investigate the root cause of damaged bottom plate removed from an above ground vertical storage tank bottom plate. The NDE techniques used for the root cause analysis (RCA) included Visual and Low-Power Optical Microscopic Examination, hardness testing, Metallographic Examination and surface roughness examination. Based on concluding facts,