Please use this identifier to cite or link to this item:
http://dspace.uniten.edu.my/jspui/handle/123456789/13292
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sabri, M.H.M. | en_US |
dc.contributor.author | Ahmad, M.R. | en_US |
dc.contributor.author | Esa, M.R.M. | en_US |
dc.contributor.author | Periannan, D. | en_US |
dc.contributor.author | York, S.B. | en_US |
dc.contributor.author | Mohammad, S.A. | en_US |
dc.contributor.author | Abdul-Malek, Z. | en_US |
dc.contributor.author | Lu, G. | en_US |
dc.contributor.author | Zhang, H. | en_US |
dc.contributor.author | Yusop, N. | en_US |
dc.contributor.author | Cooray, V. | en_US |
dc.contributor.author | Al-Kahtani, A.A. | en_US |
dc.contributor.author | Ab Kadir, M.Z.A. | en_US |
dc.contributor.author | Hatta, N.M. | en_US |
dc.contributor.author | Abdullah, N. | en_US |
dc.contributor.author | Yahaya, M.P. | en_US |
dc.date.accessioned | 2020-02-03T03:31:37Z | - |
dc.date.available | 2020-02-03T03:31:37Z | - |
dc.date.issued | 2019 | - |
dc.identifier.uri | http://dspace.uniten.edu.my/jspui/handle/123456789/13292 | - |
dc.description.abstract | The environmental conditions leading to the bouncing-wave discharge and the subsequent electron beam remain to be investigated in more detailed future studies. The analysis of quasi-static initial electric field changes (IECs) were found at the beginning of all 24 lightning flashes detected within reversal distance (22 Negative Cloud-to-Ground (–CG) and 2 normal Intra-Cloud (IC) flashes) in a tropical storm on June 15th, 2017 close to our station in Malacca, Malaysia (2.314077° N, 102.318282° E). The IECs durations averaged 4.28 ms for –CG flashes (range 1.48 to 9.45 ms) and averaged 11.30 ms for normal ICs flashes (range 7.24 to 15.35 ms). In comparison to Florida storms, the duration of IECs for –CG and IC flashes were 0.18 ms (range 0.08 to 0.33 ms) and 1.53 ms (range 0.18 to 5.70 ms), respectively. Moreover, the magnitudes of E-change for tropical thunderstorm were 0.13 V/m (range 0.03 to 0.44 V/m) for –CG flashes and-0.20 V/m (range-0.13 to-0.27 V/m) for IC flashes. The E-change magnitudes of tropical flashes are significantly larger than Florida flashes. © Foundation Environmental Protection & Research-FEPR. | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | Ekoloji | en_US |
dc.title | Environmental analysis of quasi-static electric field changes of tropical lightning flashes | en_US |
dc.type | Article | en_US |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | Universiti Tenaga Nasional | - |
Appears in Collections: | UNITEN Scholarly Publication |
Files in This Item:
File | Size | Format | |
---|---|---|---|
environmental-analysis-of-quasi-static-electric-field-changes-of-tropical-lightning-flashes-5604.pdf | 493.18 kB | Adobe PDF | View/Open |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.