  • Tenaga Nasional Berhad (UNITEN, 1996)
    The functions of the generator gas system are safely supply generator with hydrogen gas using carbon dioxide as the scavenging medium, maintain generator hydrogen at the proper pressure, temperature and purity, safely ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The function of Burner Management System is to provide sequencing monitoring and interlocks for the fuel oil warming, furnace purge, main fuel trip (MFT), ignition fuel trip (IFT), fuel oil trip (FOT), fuel gas trip (FGT), ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The functions of the turbine bypass system are reduce the unit start-up time by overcoming the furnace exit gas temperature limitations. This is achieved by establishing steam flow through the turbine bypass system to the ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The function of the condenser air removal system are create the initial vacuum in the condenser during unit start-up, continuously remove air and non-condensible gases from the condenser during normal unit operation, ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The function of the Condensate System are to, deliver condensate from the main condenser hotwell to the deaerator, supply condensate to the seal water header, supply condensate to the turbine exhaust hood sprays, LP turbine ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The primary purpose of the chemical dosing system is to inject chemicals into and thus maintain a desired quality process fluids like feedwater, boiler water and condensate to attain optimum life of boiler tubes,piping and ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The function of the Boiler Ignition System are to, provide a supply of ignition fuel gas to the boiler igniters, provide a reliable source of ignition at each main fuel burner
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The functions of the Boiler Auxiliary Cooling Water (BACW) System are to, secure the supply of cooling water for the boiler auxiliaries, provide cooling water to the instrument and station air compressors, provide cooling ...
  • Tenaga Nasional Berhad (UNITEN, 1996)
    The functions of the Sootblower system are maintain the thermal efficiency of the boiler by removing ash and soot adhering on the superheaters, reheaters and economiser tube surfaces, remove soot, ash and fouling deposits ...
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (UNITEN, 1996)
  • Tenaga Nasional Berhad (Universiti Tenaga Nasional, 1996)
  • Tenaga Nasional Berhad (Tenaga Nasional Berhad, 1996)
  • Tenaga Nasional Berhad (UNITEN, 1996)