Please use this identifier to cite or link to this item: http://dspace.uniten.edu.my/jspui/handle/123456789/8989
Title: Power-loss breakdown of a 750-V 100-kW 20-kHz bidirectional isolated DC-DC converter using SiC-MOSFET/SBD dual modules
Authors: Akagi, H. 
Yamagishi, T. 
Tan, N.M.L. 
Miyazaki, Y. 
Kinouchi, S.-I. 
Koyama, M. 
Issue Date: 2015
Abstract: This paper describes the design, construction, and testing of a 750-V 100-kW 20-kHz bidirectional isolated dual-active-bridge dc-dc converter using four 1.2-kV 400-A SiC-MOSFET/SBD dual modules. The maximum conversion efficiency from the dc-input to the dc-output terminals is accurately measured to be as high as 98.7% at 42-kW operation. The overall power loss at the rated-power (100 kW) operation, excluding the gate-drive and control circuit losses, is divided into the conduction and switching losses produced by the SiC modules, the iron and copper losses due to magnetic devices, and the other unknown loss. The power-loss breakdown concludes that the sum of the conduction and switching losses is about 60% of the overall power loss and that the conduction loss is nearly equal to the switching loss at the 100-kW and 20-kHz operation. © 1972-2012 IEEE.
URI: http://dspace.uniten.edu.my/jspui/handle/123456789/8989
Appears in Collections:COE Scholarly Publication

Show full item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.